Email updates

Keep up to date with the latest news and content from Malaria Journal and BioMed Central.

Open Access Highly Accessed Methodology

Comparison of three molecular methods for the detection and speciation of Plasmodium vivax and Plasmodium falciparum

Prapaporn Boonma1, Peter R Christensen2, Rossarin Suwanarusk2, Ric N Price23, Bruce Russell2* and Usa Lek-Uthai1*

Author Affiliations

1 Department of Parasitology, Faculty of Public Health, Mahidol University, Bangkok, Thailand

2 International Health Program, Infectious Diseases Division, Menzies School of Health Research and Charles Darwin University, Darwin, Australia

3 Centre for Vaccinology & Tropical Medicine, Nuffield Department of Clinical Medicine, John Radcliffe Hospital, Oxford, UK

For all author emails, please log on.

Malaria Journal 2007, 6:124  doi:10.1186/1475-2875-6-124

Published: 15 September 2007

Abstract

Background

Accurate diagnosis of Plasmodium spp. is essential for the rational treatment of malaria. Despite its many disadvantages, microscopic examination of blood smears remains the current "gold standard" for malaria detection and speciation. PCR assays offer an alternative to microscopy which has been shown to have superior sensitivity and specificity. Unfortunately few comparative studies have been done on the various molecular based speciation methods.

Methods

The sensitivity, specificity and cost effectiveness of three molecular techniques were compared for the detection and speciation of Plasmodium falciparum and Plasmodium vivax from dried blood spots collected from 136 patients in western Thailand. The results from the three molecular speciation techniques (nested PCR, multiplex PCR, and real-time PCR) were used to develop a molecular consensus (two or more identical PCR results) as an alternative gold standard.

Results

According to the molecular consensus, 9.6% (13/136) of microscopic diagnoses yielded false negative results. Multiplex PCR failed to detect P. vivax in three mixed isolates, and the nested PCR gave a false positive P. falciparum result in one case. Although the real-time PCR melting curve analysis was the most expensive method, it was 100% sensitive and specific and least time consuming of the three molecular techniques investigated.

Conclusion

Although microscopy remains the most appropriate method for clinical diagnosis in a field setting, its use as a gold standard may result in apparent false positive results by superior techniques. Future studies should consider using more than one established molecular methods as a new gold standard to assess novel malaria diagnostic kits and PCR assays.